Franklin Hodge

Induced draught cooling towers
Share via:
Share via:

Induced Draught Cooling Towers

Induced draught cooling towers use an axial fan at the top of the tower to draw air up through the fill and discharge it clear of the air inlet. That reduces recirculation of warm, wet air and gives even airflow across the tower. Franklin Hodge builds induced draught cooling towers as the Carter Environmental BUC series, from 6 to 600 cubic metres per hour.

 

How an Induced Draught Cooling Tower Works 

 

An induced draught tower pulls air rather than pushing it. The fan sits at the top and draws air up through the counterflow fill, against the falling water, then discharges saturated air high above the inlet. Drawing air this way spreads it evenly through the fill and pushes the warm plume clear, so you get consistent cooling and less chance of the tower breathing its own exhaust. 

 

The Carter BUC Induced Draught Cooling Tower 

 

The BUC series is an induced-draught, counterflow tower with direct-drive duct axial fans at the top. It runs from 6 to 600 cubic metres per hour, comes as single or multi-cell units, and is available in open or closed-circuit variants. Direct-drive fans mean fewer moving parts than a belt system, which keeps maintenance straightforward. Multi-cell layouts give you built-in redundancy, so one cell can stay in service while another is maintained. Drift eliminators capture water droplets before the air leaves the tower, which cuts water loss and keeps the discharge clean. 

 

Induced Draught vs Forced Draught Cooling Towers 

 

The difference is where the fan sits and which way it moves air. An induced draught tower draws air out from the top, which cuts recirculation and suits open outdoor sites. A forced draught tower blows air from the base, which suits tight or indoor spaces. We build both across our evaporative cooling towers range, so we will point you to whichever fits your layout rather than pushing one design. 

 

Induced Draught Cooling Tower Applications 

 

Induced draught towers handle heat rejection for industrial processes, HVAC plants and large commercial sites. Where energy use matters, high-efficiency fans and controls cut running costs, and we can assess existing units before recommending a like-for-like or upgraded replacement. 

 

Servicing, Refurbishment and Spare Parts 

 

We design, build and maintain every induced draught cooling tower we supply. That means OEM cooling tower refurbishment and genuine spare parts for the life of the unit. Our towers are built for market-leading access too, with features such as cooling tower ladders that keep servicing quick and safe. 

 

Speak to Franklin Hodge About Induced Draught Cooling 

 

Send us your duty, flow rate and site details, and we will confirm whether the BUC induced draught tower is the right fit and size for your load. Contact us for a specification and lead time, and we will respond with the details. 